INTERCURE 200 HS PDF

INTERCURE 200 HS PDF

A fast drying reputation isn’t all Intercure® HS is renowned for. Complete with MIO, this primer/intermediate can improve your productivity and lower your. Allow appropriate loss factors. Airless Spray, Air Spray, Brush, Roller. PRACTICAL. INFORMATION FOR. INTERCURE Colour. Gloss Level. Volume Solids. A fast drying reputation isn’t all International Intercure HS is renowned for. Complete with MIO, this Fast cure anti-corrosive primer/intermediate with added.

Author: Mezibar Mishicage
Country: Namibia
Language: English (Spanish)
Genre: Spiritual
Published (Last): 3 November 2016
Pages: 142
PDF File Size: 17.4 Mb
ePub File Size: 14.67 Mb
ISBN: 239-9-75599-247-6
Downloads: 81171
Price: Free* [*Free Regsitration Required]
Uploader: Maukus

Surface preparation All surfaces to be coated should be clean, dry and free from contamination. Varnish Hybrid Water base.

International Intercure HS – Rawlins Paints

Other content by this manufacturer: Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with intercuer mixed units. The minimum purchase order quantity for the product is 1.

This product is not available in pale and pastel shades due to a tendency to discolour rapidly. VOC values are typical and are provided for guidance purpose only. We recommend that Customer first purchases the smallest Product available or access an industry standard colour chart in person and not digitally to ensure that the colour is acceptable for its purposes.

Consult International Protective Coatings for further details. It can also be used as a primer for substrates other than blasted steel, e.

Over-application of Intercure HS will extend both the minimum overcoating periods and handling times, and may be detrimental to long term overcoating properties.

Prior to paint application, all surfaces should be assessed and treated in accordance with ISO Intercure HS will normally be applied to suitably prepared steel, e. If oxidation has occurred between blasting and application of Intercure HS the surface should be reblasted to the specified visual standard.

  DIFFERENTIAL GEOMETRY LIE GROUPS AND SYMMETRIC SPACES HELGASON PDF

Not intended for use as a primer for steelwork which may be subjected to continuous immersion conditions.

INTERCURE HS – SAND (KIT / 4G) – L

The surface may deteriorate to Sa2 standard but must be free from loose powdery deposits. Mouse over image to zoom. Be the first to write a review for this product! International Paint Ltd Web: Low molecular weight reactive additives, which will form part of the film during normal ambient cure conditions, will also effect VOC values determined using EPA Method The question has been correctly sent.

Press and move to zoom. GTA Do not thin more than allowed by local environmental legislation Mix ratio: The figures stated above are approximate.

Intercure® 200HS

Low trade 2200 Our best trade prices on everything! Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. The content of this website is our best recommendation and is not advice.

Suitable for overcoating within seven hours in most climatic conditions. Hw, in common with all epoxies Intercure HS will chalk on exterior exposure. Work stoppages Do not allow material to remain in hoses, gun or spray equipment.

Intercure HS can also be used as a primer inyercure substrates other than blasted steel, e. Each product clause is authored in NBS format and is intended for inclusion in project specifications. Consult International Protective Coatings for further details. It is good working practice to periodically flush out spray equipment during the course of the working day. This product is no longer in stock Red.

If the shop primer shows extensive or widely scattered breakdown overall sweep blasting maybe necessary.

  AS 2118.1 PDF

International Intercure 200HS

As a primer for steelwork intended for use in a wide range of environmental conditions including offshore, chemical and petrochemical plants, industrial buildings, pulp and paper mills, power plants and bridges.

However, if necessary, application over prefabrication blast primers can be performed. I would like to hear about offers and services: Surface defects revealed by the blast cleaning process should be ground, filled, or treated in the appropriate manner. These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances. However, if necessary, application over prefabrication blast primers can be performed. Once the unit has been mixed, it must be used within the working pot life specified.

Please ensure you refer to all datasheets for full application information. International Intercure HS Reference: This product must only be thinned using recommended International GTA thinners.

Provides quick cure even at low temperatures often encountered in maintenance painting. Intercure HS is suitable for application to blast cleaned surfaces which were initially to the above standard but have been allowed to deteriorate under good shop conditions for intercurw to days.

Systems compatibility Intercure HS will normally be applied to suitably prepared steel, e. Suitable for overcoating within 7 hours in most climatic conditions hence speeding up production and throughput in fabrication shops.

However, these phenomena are not detrimental to anti-corrosive performance.

Provides quick cure even at low temperatures often encountered in maintenance painting.