AATCC 183 PDF

AATCC 183 PDF

UV RESISTANCE / PROTECTION UPF- Ultraviolet protection factor rating. Ultraviolet Protection (UPF) 15 – 50+ Test Methods – AATCC AATCC Transmittance or Blocking of Erythemally Weighted Ultraviolet Radiation through Fabrics. standard by American Association of Textile. work, e.g. AATCC with ASTM D and. ASTM D in the United States and EN in. Europe. The Australian Radiation Protection and.

Author: Zulkizilkree Mezihn
Country: Djibouti
Language: English (Spanish)
Genre: Music
Published (Last): 24 July 2008
Pages: 245
PDF File Size: 18.92 Mb
ePub File Size: 20.74 Mb
ISBN: 960-5-40641-516-3
Downloads: 11975
Price: Free* [*Free Regsitration Required]
Uploader: Marn

The integrating sphere surface is internally coated or constructed using a material that is both diffuse and highly reflecting in the ultraviolet region. However, because the fluorescent component does not contribute to the UPF, the spectral distribution of the source is irrelevant, so long as it provides sufficient energy to cover the spectral range of interest to acceptable signal to noise ratios in the spectral data.

American standards for UV-protective textiles.

The effects of fluorescence are, therefore, eliminated at most UVR wavelengths. Press and move the specimen from time to time to ensure a good and uniform penetration.

All OSHA standards and rules must also be consulted and followed. Filter, Schott Glass UG11 see Avoid distorting the specimen during preparation and handling.

The intervals in Table I are in 2 nm. Prepare only one specimen at a time. This includes nearly all wavelengths in the UVR spectral region. The cross-sectional area of the illuminating beam shall be at least 10 times the dimension of the largest hole in the test material. Wear prescribed safety glasses in all laboratory areas.

The contribution of sample fluorescence on spectral transmittance measurements on certain dyes and whitening agents present in fabrics that may fluoresce could result in artificially high values of spectral transmittance. Record the individual measurements. The limits of the spectral range of ultraviolet radiation are not well defined and may vary according to the user. It must be noted that stretching the specimens could change the UPF properties. There is no independent method for determining the true value.

  DAVID GROSSMAN CI SONO BAMBINI A ZIG ZAG PDF

AATCC 紫外辐射通过织物的透过或阻挡性能_百度文库

Between-laboratory precision has not been established for this test method. Thoroughly wet out the specimen in distilled water by placing it flat in the bottom of a beaker and then pour distilled water into the beaker until the specimen is covered.

The measured wavelength interval over this spectral range should not be greater than 5 nm. Calibrate the spectrophotometer or spectroradiometer according to manufacturer instructions. The spectrophotometer or spectroradiometer shall have a spectral bandpass of 5 nm or aacc over the spectral range of nm or less to nm or more. Illumination and viewing geometries.

The contribution of stray radiation within the instrument, including that due to sample fluorescence, shall produce an error of less than 0.

AATCC Launches New Tools for Testing UV-Protective Fabrics

Atcc specimen is viewed unidirectionally with an axis not greater than 0. Instrument Verification and Calibration 5. Allow aatdc specimen to remain submerged for 30 minutes. Avoid evaporative reduction of the moisture content below the specified level before the actual UV transmission measurements are made. In this geometry the specimen is illuminated by an internally illuminated integrating sphere. In Marchan ul- A1. Apparatus and Materials 8. If the fabric has low moisture absorption, repeat the soaking and wringing steps.

Although integration is indicated from nm to the stated wavelengths, little or no contribution will occur in the nm region. Aatfc such precision information is available, users of the method should use standard statistical techniques in making any comparison of test results for betweenlaboratory averages.

  APRENDER A JARDINAR PDF

UV Resistance / Protection Test: AATCC 183 , ASTM D655, ASTM D6603

The use of an illuminating light source that conforms to the spectral distribution requirements for solar simulators will most accurately include the contribution of sample fluorescence to the long wavelength UVA measurement. Purpose and Scope 1.

The precautions are ancillary to the testing procedures and are not intended to be all inclusive. Uses and Limitations 3.

However, the techniques for stretching the specimens are not part of this method and are addressed in a separate test procedure. Principle ance transmitted and calculated through air to the average effective UV-R irradiance transmitted and calculated through fabric.

Precision and Bias The error can be eliminated in either geometry by use of a separate reference beam that traverses its own port opening in the sphere.

Transmittance or blocking of erythemally weighted ultraviolet radiation through fabrics can be defined only in terms of a test method. The error due to the fluorescence can be removed by placing a UV transmitting, visible blocking filter after the sample. Any ray of this beam shall not exceed 0. In this geometry the specimen is illuminated with an unidirectional beam whose axis is not greater than 0.

Note, some samples may not be capable of achieving the specified wet pick-up such as tightly woven synthetic fabrics.

Appendix A Spectrophotometer or Spectroradiometer Specifications The intervals in Table II are in 2 nm.

Previous post: